LeadershipInnovation at WSUResearchDirectoriesGive to WSUmyWSUOneStop
ACADEMICSADMISSIONSSTUDENT LIFEATHLETICSABOUTAPPLY NOW
  • Leadership
  • Innovation at WSU
  • Research
  • Directories
  • Give to WSU
  • myWSU
  • OneStop
  • Academic Calendar
  • Apply Now!
  • A-Z Directory
  • Blackboard
  • Campus Events
  • Careers and Employment
  • Office Hours
  • Policies and Procedures
  • Schedule of Courses
  • ShockerSync - Student Events
  • Shocker Store
  • Student Webmail
  • Technology HelpDesk
  • Transfer to WSU
  • University Libraries
Wichita State University LogoWichita State University Logo
ACADEMICSADMISSIONSSTUDENT LIFEATHLETICSABOUTAPPLY NOW

Search Results for “instructional design”

5,225 results · showing 5201–5220 · partial match · 728 ms

Search Results

  1. PDF

    BT250E-6-NCAMP-Material-Base-Specification

    …1.2 Application: These composite prepreg material systems are intended for use in the fabrication of aerospace structures and tooling substrate. The materials are designed specifically for vacuum-bag autoclave cure in accordance with NPS 81250 baseline cure cycle “C”. They are typically used in structural applications requiring high strength and…

    https://www.wichita.edu/industry_and_defense/NIAR/Research/tencate-bt250e-6/BT250E-6-NCAMP-Material-Base-Specification.pdf

  2. PDF

    5250-5-NCAMP-Material-Base-Specification

    …Applications may include engine nacelles, fuselage skin and stiffeners, wing and stabilizer spars and skins, and other load-bearing components. The materials are designed for autoclave cure in accordance with NPS 81226 baseline cure cycle “C.” Material property data including statistically based material allowables are available publicly for the…

    https://www.wichita.edu/industry_and_defense/NIAR/Research/cytec-5250-5/5250-5-NCAMP-Material-Base-Specification.pdf

  3. PDF

    EP2202-NCAMP-Material-Base-Specification

    …1.2 Application: These composite prepreg material systems are intended for use in the fabrication of aerospace structures and tooling substrate. The materials are designed specifically for vacuum-bag autoclave cure in accordance with NPS 82202 baseline cure cycle “C”. They are typically used in structural applications requiring high strength and…

    https://www.wichita.edu/industry_and_defense/NIAR/Research/cytec-ep2202/EP2202-NCAMP-Material-Base-Specification.pdf

  4. PDF

    NCAMP-Repair-Equivalence-Report_Laminate-Repair-Prepreg-NCP-RP-2018-017-RevNC-12-19-19-SAR-Final

    …of a type I error is set at 5%. These tests are performed with the HYTEQ spreadsheet, which was designed to test equivalency between two materials in accordance with the requirements of CMH-17-1G section 8.4.1: Tests for determining equivalency between an existing database and a new dataset for the same material. Details about the methods used are…

    https://www.wichita.edu/industry_and_defense/NIAR/Documents/NCAMP-Repair-Equivalence-Report_Laminate-Repair-Prepreg-NCP-RP-2018-017-RevNC-12-19-19-SAR-Final.pdf

  5. PDF

    School_Counseling_Practicum_and_Internship_Handbook_SP21

    …on blackboard and Tevera, and there are numerous forms designed to facilitate your learning process and verify information for Kansas licensure and certification. Many of the forms you will be using this semester will remain in your department file as verification of your field experience coursework. It is in your best interest to complete all…

    https://www.wichita.edu/academics/education/cles/_documents/School_Counseling_Practicum_and_Internship_Handbook_SP21.pdf

  6. PDF

    Annual_Security_Report_2022

    …Fire Safety Report POLICIES CONCERNING SECURITY, ACCESS AND MAINTENANCE OF CAMPUS FACILITIES LAW ENFORCEMENT JURISDICTION/ACCURATE AND PROMPT REPORTING ... 28 29 PROGRAMS DESIGNED TO INFORM STUDENTS AND EMPLOYEES ABOUT CAMPUS SECURITY AND PREVENTION ... 30 ALCOHOL POLICY .. 31 POLICY REGARDING DRUG LAWS 32 DRUG OR ALCOHOL ABUSE EDUCATION PROGRAMS…

    https://www.wichita.edu/about/clery/_documents/Annual_Security_Report_2022.pdf

  7. PDF

    NCP-RP-2010-002-Rev-NC-MTM45-1-AS4-PW-M-Cure-Equivalency-Statistical-Analysis-Report-3-21-19

    …I error is set at 5%. These tests are performed with the HYTEQ spreadsheet, which was designed to test equivalency between two materials in accordance with the requirements of CMH-17-1G section 8.4.1: Tests for determining equivalency between an existing database and a new dataset for the same material. Details about the methods used are documented in the…

    https://www.wichita.edu/industry_and_defense/NIAR/Research/cytec-mtm45-1/NCP-RP-2010-002-Rev-NC-MTM45-1-AS4-PW-M-Cure-Equivalency-Statistical-Analysis-Report-3-21-19.pdf

  8. PDF

    NCP-RP-2009-002-Rev-NC-IM7-LH-cure-cycle-Equivalence-Report-3-21-19

    …which was designed to test equivalency between two materials in accordance with the requirements of CMH-17-1G section 8.4.1: Tests for determining equivalency between an existing database and a new dataset for the same material. Details about the methods used are documented in the references listed in Section 5. Page 11 of 39 March 21, 2019 n …

    https://www.wichita.edu/industry_and_defense/NIAR/Research/cytec-mtm45-1/NCP-RP-2009-002-Rev-NC-IM7-LH-cure-cycle-Equivalence-Report-3-21-19.pdf

  9. PDF

    NCP-RP-2010-001-Rev-NC-MTM45-1-AS4-PW-LH-Cure-Equivalency-Statistical-Analysis-Report-3-21-19

    … error is set at 5%. These tests are performed with the HYTEQ spreadsheet, which was designed to test equivalency between two materials in accordance with the requirements of CMH-17-1G section 8.4.1: Tests for determining equivalency between an existing database and a new dataset for the same material. Details about the methods used are documented in the…

    https://www.wichita.edu/industry_and_defense/NIAR/Research/cytec-mtm45-1/NCP-RP-2010-001-Rev-NC-MTM45-1-AS4-PW-LH-Cure-Equivalency-Statistical-Analysis-Report-3-21-19.pdf

  10. PDF

    NCP-RP-2008-008-Rev-NC-IM7-M-cure-Equivalence-Report-3-21-19

    …tests are performed with the HYTEQ spreadsheet, which was designed to test equivalency between two materials in accordance with the requirements of CMH-17-1G section 8.4.1: Tests for determining equivalency between an existing database and a new dataset for the same material. Details about the methods used are documented in the references listed in…

    https://www.wichita.edu/industry_and_defense/NIAR/Research/cytec-mtm45-1/NCP-RP-2008-008-Rev-NC-IM7-M-cure-Equivalence-Report-3-21-19.pdf

  11. PDF

    NCP-RP-2010-010-Rev-NC-MTM45-1-3K-PW-G30-500-LH-Cure

    …of a type I error is set at 5%. These tests are performed with the HYTEQ spreadsheet, which was designed to test equivalency between two materials in accordance with the requirements of CMH-17-1G section 8.4.1: Tests for determining equivalency between an existing database and a new dataset for the same material. Details about the methods used are…

    https://www.wichita.edu/industry_and_defense/NIAR/Research/cytec-mtm45-1/NCP-RP-2010-010-Rev-NC-MTM45-1-3K-PW-G30-500-LH-Cure.pdf

  12. PDF

    SHS_Annual_Report_FY2024

    …begins soon! 5. New in-house laboratory tests options: Bringing more in-house options for our laboratory testing menu, allows 100% reimbursement for services instead of paying a lab and offers same day results.

    https://www.wichita.edu/_archive/services/studenthealth/_documents/SHS_Annual_Report_FY2024.pdf

  13. Word doc

    PT_3.9.2020_minutes

    … Maybe starting with levels in the pandemic plan would help. Input from State and County health departments could help design these levels and their responses. Example: For a Level 1 person under investigation for being positive needs to have certain items completed. Then Level 2 for a confirmed case of COVID-19 would have different items. Etc. Each level…

    https://www.wichita.edu/_archive/services/studenthealth/_documents/PT_3.9.2020_minutes.docx

  14. PDF

    Toray-TC1225-LM-PAEK-T700GC-UNI-Qualification-NCP-RP-2025-008-RevA-2-24-2026-SAR-Final

    …The material property data acquisition process is designed to generate basic material property data with sufficient pedigree for submission to Complete Documentation sections of the Composite Materials Handbook (CMH-17) Volume 1. The NCAMP shared material property database contains material property data of common usefulness to a wide range of aerospace …

    https://www.wichita.edu/industry_and_defense/NIAR/Documents/Toray-TC1225-LM-PAEK-T700GC-UNI-Qualification-NCP-RP-2025-008-RevA-2-24-2026-SAR-Final.pdf

  15. PDF

    NCP-RP-2008-009-Rev-NC-MTM45-1-AS4-145-M-Cure-Cycle

    …I error is set at 5%. These tests are performed with the HYTEQ spreadsheet, which was designed to test equivalency between two materials in accordance with the requirements of CMH-17-1G section 8.4.1: Tests for determining equivalency between an existing database and a new dataset for the same material. Details about the methods used are documented in the …

    https://www.wichita.edu/industry_and_defense/NIAR/Research/cytec-mtm45-1/NCP-RP-2008-009-Rev-NC-MTM45-1-AS4-145-M-Cure-Cycle.pdf

  16. PDF

    NCP-RP-2019-001RevNCMTM45-1AS4-145LHCureCycle

    … I error is set at 5%. These tests are performed with the HYTEQ spreadsheet, which was designed to test equivalency between two materials in accordance with the requirements of CMH-17-1G section 8.4.1: Tests for determining equivalency between an existing database and a new dataset for the same material. Details about the methods used are documented in the…

    https://www.wichita.edu/industry_and_defense/NIAR/Research/cytec-mtm45-1/NCP-RP-2019-001RevNCMTM45-1AS4-145LHCureCycle.pdf

  17. PDF

    Additional-Documents-1

    …and liberal (lower) with regard to computations for equivalence described in section 8.4. Comparing the results of the generic approach to the CMH17 methodology, the drop in design values is exceeded by the drop in acceptance criteria. Another advantage of the generic approach is that those basis values can be used even when the production facility for a…

    https://www.wichita.edu/industry_and_defense/NIAR/Research/hexcel-8552/Additional-Documents-1.pdf

  18. PDF

    NCAMP-Repair-stats-report-NCP-RP-2020-010-RevNC-2-8-2021

    …coefficient of variation method are also provided. Page 7 of 66 February 8, 2021 NCP-RP-2020-010 Rev N/C The material property data acquisition process is designed to generate basic material property data with sufficient pedigree for submission to Complete Documentation sections of the Composite Materials Handbook (CMH-17-1G). Part fabricators that…

    https://www.wichita.edu/industry_and_defense/NIAR/Documents/NCAMP-Repair-stats-report-NCP-RP-2020-010-RevNC-2-8-2021.pdf

  19. PDF

    NCP-RP-2023-007-RevNC-Markforged-OFRA-CFRA-SAR-11.10.2023

    …These methods were described in the original MILHDBK17 and are statistically valid regardless of the material type. The material property data acquisition process is designed to generate basic material property data with sufficient pedigree for submission to Complete Documentation sections of the Composite Materials Handbook (CMH-17 Rev G). The NCAMP…

    https://www.wichita.edu/industry_and_defense/NIAR/Documents/NCP-RP-2023-007-RevNC-Markforged-OFRA-CFRA-SAR-11.10.2023.pdf

  20. PDF

    ULTEM-9085-Stat-Analysis-Report-NCP-RP-2018-007-RevA-6-17-2019

    …approach is included in CMH-17-1G, it has not yet been evaluated for use with additive manufacturing materials. The material property data acquisition process is designed to generate basic material property data with sufficient pedigree for submission to Complete Documentation sections of the Composite Materials Handbook (CMH-17 Rev G). The NCAMP shared …

    https://www.wichita.edu/industry_and_defense/NIAR/Documents/ULTEM-9085-Stat-Analysis-Report-NCP-RP-2018-007-RevA-6-17-2019.pdf

  • First
  • Previous
  • Page 257
  • Page 258
  • Page 259
  • Page 260
  • Page 261
  • Page 262
  • Next
  • Last
WSU logo
1845 Fairmount St.
Wichita, Kansas  67260
USA
(316) 978-3456
Request InfoVisitApply
Contact UsVirtual TourInteractive Map and Directions
WSU Foundation and Alumni Engagement logoShocker Store LogoAge Friendly University logo
FacebookX | TwitterInstagramYouTubeLinkedin
(WSU) is unique in how many excellent opportunities students have to get relevant experience on their resume while in college.
Sarah Varner , aerospace engineering major
Alumni & FriendsGive to WSU
  • A-Z Index
  • Careers and Employment
  • Freedom of Expression
  • Policies and Procedures
  • Privacy Policy
  • Notice of Nondiscrimination
  • Title IX
  • Campus Safety
  • Accessibility
  • Public Information
  • Website Support
  • KBOR Freedom of Expression Statement
  • HLC Accreditation

© 2026 Wichita State University

footer-lbbgogo
Wichita State University (“WSU”) does not discriminate on the basis of sex in its education programs, activities, admissions and employment.